logo
خانه محصولاتسنسور گاز

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

گواهی
چین ShenzhenYijiajie Electronic Co., Ltd. گواهینامه ها
چین ShenzhenYijiajie Electronic Co., Ltd. گواهینامه ها
چت IM آنلاین در حال حاضر

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor
YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

تصویر بزرگ :  YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

جزئیات محصول:
محل منبع: سوئیس
نام تجاری: YJJ
شماره مدل: NH3/CR-50
پرداخت:
مقدار حداقل تعداد سفارش: 1
قیمت: قابل مذاکره
جزئیات بسته بندی: بسته جعبه
زمان تحویل: 5-8 روز
شرایط پرداخت: L/C ، D/A ، D/P ، T/T ، Western Union ، MoneyGram
قابلیت ارائه: 1500

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

شرح
دامنه اندازه گیری: 0 ~ 100ppm زندگی: 2 سال در هوا
سیگنال خروجی: 90 ± 18NA/ ppm وضوح: 1ppm
دامنه دما: -10 درجه سانتیگراد تا 40 درجه سانتیگراد زمان پاسخ (T90): <60 ثانیه
دامنه رطوبت: 15 ٪ تا 90 ٪ خط مبنا: 0ppm ± 4ppm
برجسته کردن:

electrochemical ammonia gas sensor,liquid ammonia leakage detector,NH3 CR-50 gas sensor

,

liquid ammonia leakage detector

,

NH3 CR-50 gas sensor

Product Description:

YJJ NH3/CR-50 Electrochemical Ammonia Gas Sensor Is Used As A Liquid Ammonia Leakage Sensor

 

Features:

Ammonia gas sensor (NH3 sensor)

NH3/CR-200,NH3/MR-100,NH3/S-200,NH3/CR-1000,NH3/MR-1000,

NH3/CB-200 completely replaces 7AM, 7NH and A7AM in UK CITY

NH3/SB-200 completely replaces 3AM in UK CITY

NH3/MR-100 completely replaces 4AM in UK CITY

Technical parameters of NH3 sensor:

NH3/CR-200

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 90±18nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <60sec

Humidity range: 15%to90%

Baseline: 0ppm±4ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

NH3/MR-100

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 120±30nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <50sec

Humidity range: 15%to90%

Baseline: 0ppm±3ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

NH3/SR-200

Measurement range: 0 ~ 100ppm

Maximum load: 200ppm

Service life: 2 years in air

Output signal: 90±18nA/ PPM

Resolution: 1 PPM

Temperature range: -10°C to 40°C

Response time (T90) : <60sec

Humidity range: 15%to90%

Baseline: 0ppm±4ppm

Typical signal drift: <5% per 6 months

Recommended loading resistance: 10 Ohm

Bias voltage: not required

 

Specifications:

Detection of gas NH3
range 0-20ppm
Maximum limit of measurement 250ppm
The sensitivity 1±0.25 uA/ppm

 