logo
خانه محصولاتسنسور جریان هوای پزشکی

YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control

گواهی
چین ShenzhenYijiajie Electronic Co., Ltd. گواهینامه ها
چین ShenzhenYijiajie Electronic Co., Ltd. گواهینامه ها
چت IM آنلاین در حال حاضر

YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control

YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control
YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control

تصویر بزرگ :  YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control

جزئیات محصول:
محل منبع: ایالات متحده
نام تجاری: YJJ
شماره مدل: AWM2100V
پرداخت:
مقدار حداقل تعداد سفارش: 1
قیمت: قابل مذاکره
جزئیات بسته بندی: بسته جعبه
زمان تحویل: 5 تا 8 روز کاری
شرایط پرداخت: L/C، D/A، D/P، T/T، Western Union، MoneyGram
قابلیت ارائه: 1500

YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control

شرح
اندازه پورت: 5.08 میلی متر مواد پوسته: سیلیکون
حداکثر دمای عملیاتی: + 85 °C حداقل دمای عملیاتی: - 25 درجه سانتیگراد
حداکثر ولتاژ منبع تغذیه: 15 V حداقل ولتاژ منبع تغذیه: 8 ولت
برجسته کردن:

YJJ AWM2100V gas flow sensor,HVAC control air flow sensor,medical analog flow sensor

,

HVAC control air flow sensor

,

medical analog flow sensor

Product Description:

YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control

 

Features:

AWM2000 series gas mass flow sensor, non-amplified (mV), flow/pressure range: ±30.0 sccm; straight port type.

The AWM2000 series microbridge gas mass flow sensor is a passive device composed of two Wheatstone bridges. According to the operating specifications, a heater control circuit is also required. According to the operating specifications, a sensing bridge power supply circuit is also necessary. These two circuits are not on the packaged circuit board, so they must be provided in the application. The differential amplifier is a useful interface for the sensing bridge. It can be used to increase gain and introduce voltage bias into the sensor output.

Application: Dry Gas

Range: +/- 200 cm/min

Accuracy: 0.35 %

Output Voltage: 30 mV

Operating Power Supply Voltage: 8 V to 15 V

Port Size: 5.08 mm

Shell Material: Silicon

Trademark: Honeywell

Maximum Operating Temperature: + 85 °C

Minimum Operating Temperature: - 25 °C

Product Type: Flow Sensors

Series: AWM200 5

Subcategory: Sensors

Maximum power supply voltage: 15 V

Minimum power supply voltage: 8 V

Unit weight: 10.800 g

 

The Honeywell AWM2000 series gas mass flow sensor is a device that utilizes a silicon film and an insulated microbridge structure. Within its microstructure, there are heaters and temperature sensing elements. This bridge-type sensor can respond sensitively and rapidly to changes in the flow rate of air or other gases beneath the diaphragm. This series of products adopts advanced design and manufacturing techniques. Its microbridge structure is not only small in size but also has extremely sensitive and rapid response capabilities. It is suitable for any situation where gas flow monitoring is required.

 

 

Product damage

The AWM series micro bridge type gas mass flow sensor is not suitable for measuring liquid flow. When liquid flows through the sensor, it will damage the sensor.

Failure to follow these instructions may result in damage to the product.

Product Features

Bidirectional airflow sensing

Measurement of actual gas mass flow

Low differential pressure measurement

 

 

Product Application

HVAC air valve and damper control

Gas analyzer

Low vacuum control

Medical ventilator

Anesthesia machine

Gas calibration

 

Specifications:

Application Dry Gas
Range +/- 200 cm/min
Accuracy 0.35 %
Output Voltage 30 mV

 

YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control 0