logo
خانه محصولاتسنسور جریان هوای پزشکی

M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow

گواهی
چین ShenzhenYijiajie Electronic Co., Ltd. گواهینامه ها
چین ShenzhenYijiajie Electronic Co., Ltd. گواهینامه ها
چت IM آنلاین در حال حاضر

M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow

M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow
M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow

تصویر بزرگ :  M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow

جزئیات محصول:
محل منبع: آلمان
نام تجاری: GE
شماره مدل: M1174442-S1
پرداخت:
مقدار حداقل تعداد سفارش: 1
قیمت: قابل مذاکره
جزئیات بسته بندی: جعبه استاندارد
زمان تحویل: 3-5 روز کار
شرایط پرداخت: L/C، D/A، D/P، T/T، Western Union
قابلیت ارائه: 1000 عدد در ماه

M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow

شرح
سازنده: خدمات بهداشتی GE فروشنده برای صورتحساب: Datex-Ohmeda
فروشنده: خدمات بهداشتی GE نوع خرید: کاملاً
برجسته کردن:

medical differential pressure sensor

,

respiratory flow sensor

,

air flow sensor with warranty

M1174442-S1 Differential Pressure Flow Sensor Respiratory Flow

 

Core Features
1. Measures bidirectional airflow (inhalation/exhalation) within the breathing circuit, and calculates tidal volume, minute ventilation, and flow waveforms.
2. Operates based on the differential pressure principle: airflow passing through a restriction orifice generates a pressure differential, which the sensor converts into an electrical signal for processing by the host unit.
3. Consists of the sensor body plus a connecting tube; features plug-and-play functionality and is reusable after high-temperature sterilization.

 

Common Applications and Faults
1. Application Scenarios: Monitoring of respiratory airflow in anesthesia machines within operating rooms and ventilators within ICUs (GE HealthCare).
2. Typical Faults: Significant deviations in tidal volume, abnormal airflow waveforms, or circuit leak failures during self-tests. These issues are primarily caused by sensor aging or contamination, necessitating cleaning or replacement.
3. Installation Guidelines: Observe the correct airflow direction; perform regular cleaning; and prevent contamination of the sensor ports by moisture or secretions.

 

Specification:

Type Differential Pressure Flow Sensor (Respiratory Flow / Tidal Volume Monitoring) — GE HealthCare
Compatible Models GE 9100C, ZY9100, ZY9300 Anesthesia Machines / Ventilators
Material Transparent TPU Body + Silicone Connecting Tube (Reusable)

 